Withdrawable MCC
Withdrawable MCC solutions providing controlled access to functional units during maintenance and replacement.
MOTOR CONTROL CENTERExplore the Logstrup modular architecture, WDU withdrawable unit concept and high-power MCC/PCC applications through real product images.
The 190 mm modular frame structure enables power distribution, motor control and special control applications to be configured within the same system approach.
Withdrawable MCC solutions providing controlled access to functional units during maintenance and replacement.
MOTOR CONTROL CENTERA modular LV switchboard architecture for main and sub-distribution, with high-current and internal separation options selected to suit project requirements.
PCC / DISTRIBUTIONPlug-in and fixed functional unit options for projects where withdrawable construction is not required.
FLEXIBLE ARCHITECTURELogstrup modular switchgear offers fixed, removable and withdrawable functional unit options to support maintenance planning, future capacity growth and changing power distribution requirements. With an appropriate electrical architecture and safe isolation arrangements, other switchboard sections may remain in service during planned maintenance, where the design permits.
Logstrup modular switchgear offers configuration options with switching and protection devices from ABB, Siemens, Schneider Electric and other international manufacturers. Component selection and design verification are assessed against the specific device model and project requirements.
The busbar system and internal separation options can be configured according to different power levels and operational and maintenance requirements.
Modular busbar components enable three-, four- and five-conductor system designs. Solutions up to 8500 A have been tested for temperature rise and short-circuit withstand.
Logstrup Modular System
Steel separation of functional units, busbars and connection areas according to project requirements helps support personnel safety, maintainability and operational continuity.
IEC 61439-1/2 • Logstrup Modular System Technical article: IEC 61439 and Form 4BLogstrup supports critical infrastructure such as data centers, heavy industry, process plants and marine applications with high current capacity, modular architecture and switchgear configurations adaptable to different operating requirements.
In a 2019 MIL-S-901D high-impact shock test reported by the manufacturer, the tested Logstrup modular switchboard configuration was subjected to shock loads exceeding 100 G. This provides a technical reference for mechanical strength in naval and demanding marine applications. The reported result applies to the tested configuration and does not represent a blanket certification for every assembly.
Logstrup Modular System supports scalable low-voltage switchboard architectures for main and sub-distribution, with flexibility for capacity growth, maintenance strategies and future expansion requirements in data center applications.
A modular approach that supports phased development, capacity growth and future expansion by allowing functional units to be reconfigured as project requirements evolve.
High-power distribution applications with tested busbar solutions up to 8500 A.
Fixed, removable and withdrawable options provide flexibility for maintenance, replacement and different operating strategies.
Bus couplers can support controlled isolation of switchboard sections or alternative supply paths within a suitable electrical architecture. Source capacity, protection coordination, interlocking and the approved single-line diagram must be considered for safe operation.
Spare ACB or MCCB feeder compartments and associated connections can be prepared during the initial design to accommodate future capacity growth. Additional feeders must remain within the assembly's verified design limits and be commissioned using appropriate safe working procedures.
Modular switchgear can accommodate top or bottom cable and busway connections to suit the facility layout. Connection arrangements are determined by mechanical clearances, current ratings and approved interface details.
Logstrup Modular System combines configurable MCC and power distribution architectures for process and energy projects, with fixed, removable and withdrawable functional units selected according to operational and maintenance requirements.
Fixed, removable and withdrawable functional units allow the switchgear structure to be selected around maintenance strategy and operating requirements.
MOTOR CONTROL / MCCTested busbar solutions up to 8500 A support high-power distribution requirements within the modular switchgear platform.
PCC / POWER DISTRIBUTIONInternal separation options from Form 1 to Form 4B can be configured according to project requirements within the IEC 61439-1/2 system approach.
INTERNAL SEPARATIONYou can request a technical and commercial evaluation for MCC, PCC, withdrawable, plug-in or fixed Logstrup solutions according to your project requirements.
We have summarized the most common technical topics at the start of a project.
It is a modular low-voltage switchgear system that enables power distribution, motor control and control panels to be designed in fixed, removable or withdrawable configurations according to project requirements.
Main and sub-distribution boards, MCC panels and control panels can be designed in fixed, removable and withdrawable configurations.
The Logstrup modular busbar system provides standard and tested solutions up to 8500 A. Three-, four- and five-conductor systems can be configured.
Yes. Logstrup Modular System supports internal separation from Form 1 to Form 4B according to project requirements. The system is compliant with IEC 61439-1/2, while tested busbar solutions are available up to 8500 A depending on the selected configuration.
Yes. The modular structure, high current capacity, IEC 61439 compliance and different functional unit options support different design and expansion requirements for data center power distribution systems.
Yes. Top or bottom busway connections can be designed according to the project requirements and approved interface details. Suitability depends on current ratings, mechanical clearances and the verified switchgear configuration.
Yes. Spare ACB or MCCB feeder compartments and their associated connection provisions can be planned at the design stage. Subsequent additions must respect the assembly's verified technical limits and applicable safe working procedures.
You can contact the Panel Elektro sales and engineering team with the single-line diagram, load list, short-circuit values, switchgear layout and project specification.
You can submit technical evaluation and quotation requests for Logstrup modular switchgear systems for projects in Turkey and international markets.